Energy Client Patched Instant
Are you an trying to update software for an energy company?
In the race to reach global net-zero goals, much of the conversation focuses on and grid modernization . However, a critical but often overlooked frontier in sustainability is the software that runs on our devices. Recent research into "energy bugs"—programming errors that cause unnecessary battery drain and power consumption—has led to the development of powerful new tools like EnergyPatch and benchmarks like ECench to identify and fix these digital leaks. The Rise of the "Energy Bug" energy client patched
Attackers could send crafted JSON payloads to the client’s data-sync endpoint, leading to remote code execution (RCE) on the host machine. If your facilities management workstation ran an outdated client, an attacker could theoretically shut down HVAC systems or falsify consumption reports. Are you an trying to update software for an energy company
These inefficiencies are particularly prevalent in complex systems: energy client patched
| | Affected System/Client | Vulnerability Type | CVSS Score | Patch Status | | :--- | :--- | :--- | :--- | :--- | | CVE-2025-64125 | Nuvation Energy nCloud Platform | Client-to-Client Communication Flaw (Data Leakage) | Not specified, but Critical | Patched | | CVE-2025-40585 | Siemens Energy Services (using G5DFR) | Hardcoded Default Credentials | 9.9 (Critical) | Patched | | CVE-2025-64123 | Nuvation Energy nCloud Platform | Client-to-Client Communication Flaw (Data Leakage) | Not specified | Patched | | CVE-2025-13510 | Iskra iHUB & iHUB Lite (Smart Metering Gateways) | Missing Authentication (CWE-306) | 9.3 (Critical) | No Patch Available from Vendor | | CVE-2025-41709 | Janitza & Weidmueller Energy Meters (UMG 96RM-E, EM 750) | OS Command Injection (CWE-78) | 9.8 (Critical) | Patch Info Not Specified | | CVE-2025-30257 | Growatt Cloud Portal | Missing Authentication | Not specified | Not Specified | | CVE-2024-23784 | Energy Management Controller JH-RVB1 / JH-RV11 | Improper Access Control | Not specified | Patched | | CVE-2026-26290 | EV Energy ev.energy Platform | Insufficient Session Expiration (Session Hijacking) | 6.9 (Medium) | No Patch Available | | CVE-2020-0008 | Android LowEnergyClient (A-142558228) | Out-of-Bounds Read (Race Condition) | Low (Unreviewed) | Patched | | VAR-201301-0373 | Schneider Electric SESU Utility | Man-in-the-Middle (MITM) Spoofing (CWE-494) | Not specified | Patched |
Configuring Intrusion Detection Systems (IDS) to flag any traffic attempting to exploit the specific flaw.