Micronta Multimeter 22 212 User Manual Today
ADJ wheel until the needle covers its own reflection directly over the "0" mark on the top green/black Ohms scale.
Select the highest current range (250mA) to avoid blowing the internal fuse. micronta multimeter 22 212 user manual
Trying to measure resistance on a powered circuit will burn out the internal resistors. ADJ wheel until the needle covers its own
Set the range to OHMS, touch the probe tips together, and turn the OHM ADJ knob until the needle points to "0" on the top green scale. 2. Measuring Voltage (AC/DC) touch the probe tips together
Separate the probes and connect them across the resistor or component you wish to test. Ensure the component is completely disconnected from any power source.