The shaft is always larger than the hole, requiring force, heating, or freezing to assemble. The parts remain rigidly fixed together. Example designations: H7/p6H7/p6 H7/s6H7/s6
To determine the precise physical dimensions required during cutting, grinding, and turning operations. iso 286 pdf
: The fundamental deviation for a hole (lower limit starts at exactly : The IT grade ( The shaft is always larger than the hole,
This part contains the actual numerical data and lookup tables used by machinists and designers. Core Concepts of the ISO Limits and Fits System : The fundamental deviation for a hole (lower
The standard acts as a universal language for manufacturing. Instead of explicitly detailing exact measurement tolerances on a blueprint, an engineer can use a concise code (like H7 or g6 ) that a machinist anywhere in the world can interpret identically. The Two Parts of ISO 286
In a clearance fit, the shaft is always smaller than the hole. This guarantees that the components can slide or rotate freely relative to each other. An example of a common clearance fit is . 2. Interference Fit