Krups Error Code 09 Jun 2026
If your machine is still under warranty, contact Krups Customer Service instead of opening it, as self-repair will void your coverage.
Sensor shows open circuit/infinite resistance on multimeter. Replace the NTC sensor or the thermoblock assembly. Medium to High Zero continuity through the inline thermal cutoff fuses. Swap out the high-temperature fuses on the power line. Loose or Oxidized Contacts krups error code 09